- 1 Blink: Indicates control board self diagnostic failure. This requires a manual reset*.
- 3 Blinks: Indicates ESP (Exhaust Sensing Probe) failure. This requires a manual reset*.
- 4 Blinks: Can occur only in Room Temp Mode and indicates Room Sensing Probe failed or not installed. If a Room Sensing Probe is then installed, the status light will automatically reset. The Room Sensing Probe is the thick black wire coming out of the pellet stove/insert. NOTE: Unit will not start in “AUTO” with this status error.
- 5 Blinks (In Igniter Auto. Mode Only): Indicates that the unit has failed to light after 4 consecutive igniter cycles, 32 minutes total. To reset – Turn Mode Selector to “OFF”, then turn to either mode again.
- 6 Blinks : Indicates that the control has calculated poor or incomplete combustion occurring for more than 50 minutes. See Troubleshooting section for more details. A six blink status may be set if the stove is allowed to run out of pellets. To reset, turn mode selector to “OFF” then back on to the desired mode. If the unit was not out of pellets, see Troubleshooting section of owners manual for more details.